JUPITER IDEAL · NORIT

Dry-build underfloor heating without a wet screed

For renovators who buy the materials themselves or through their installer. With JUPITER IDEAL the pipe sits in a 20 or 30 mm system panel, topped with a thin, dry screed. No drying time, little weight and little height. Below you can read when that pays off, when it does not, and what it costs.

  • No drying time and no heating-up protocol
  • Low water temperature, ideal for a heat pump
  • System panel from 20 mm
Build-up diagram of dry-build underfloor heating: floor finish, load-spreading layer, system element with pipe and subfloor 1 Tiles + adhesive ≈ 10 mm 2 StrongBoard FL load-spreading board, 5 mm 3 NEO20 system element with 16 mm pipe, 20 mm 4 Subfloor Existing tiled floor

Renovation on a tiled floor

System panel
20 mm
Build-up
25 mm
With floor finish
≈ 35 mm
The system panel is not the same as your total build-up. Always add the load-spreading layer and the floor finish.

Why dry build

When dry build really pays off

Four ways a dry build-up differs from a wet screed. With figures, so you can check them for your own floor.

Floor height

A wet screed over underfloor heating pipes is usually 5 cm or thicker. With dry build the pipe sits in a 20 or 30 mm system panel, topped with 5 mm StrongBoard FL or 15 to 20 mm NORIT gypsum fibre. Doors, stairs and connections can often stay as they are.

Weight

StrongBoard FL weighs about 5.2 kg/m², NORIT-TE 15 about 19.6 kg/m² and NORIT-TE 20 about 26 kg/m². A 5 cm cement screed already weighs about 100 kg/m² (5 cm × about 2,000 kg/m³). That is why dry build also suits timber joist floors, provided they are stiff enough.

Installation

No water goes into the floor: no drying time, no heating-up protocol, no construction moisture. You cut the elements to size, press the pipe into the aluminium heat-conducting plates, and glue and click NORIT boards together without screws. The floor finish can go on as soon as the screed is down and the pressure test is done.

Comfort

Aluminium heat-conducting plates spread the heat across the whole surface, and there is little mass above the pipe. So the floor responds quickly and works with low water temperatures, such as from a heat pump. The IDEAL elements also insulate, so the heat goes mainly upwards, even on a ground floor. How much heat you get depends mostly on your floor finish: see the table.

The power of aluminium

In every JUPITER IDEAL element the pipe sits in an aluminium heat-conducting plate. Aluminium conducts heat about four times better than steel and hundreds of times better than EPS or gypsum fibre. The omega profile encloses the pipe all round, except for the clip-in opening at the top, so the heat passes straight from pipe to plate. The plate spreads the pipe’s heat across the full width to the next pipe, instead of only straight above it. The plates are deliberately thicker than foil or sheet: thick enough to spread the heat sideways quickly, yet so light that they add hardly any mass and therefore hardly any inertia.

  • Evenly warm floor, without cold strips between the pipes.
  • Lower water temperature for the same average floor temperature, and so the same output.
  • More efficient with a heat pump: the lower the flow temperature, the higher the efficiency.

Without aluminium: higher water temperature needed

With aluminium plate: lower water temperature is enough

average floor temperature

Schematic, not to scale. Top: without spreading, the floor mainly warms right above the pipe. Bottom: the aluminium plate spreads the heat, so the same average floor temperature is reached with cooler water.

Strong in modern construction

  • Circular: laid dry, separable and demountable, and can be reinstalled
  • Bio-based: ÖKO30 made of wood fibre, STR30 made of straw
  • Timber and lightweight construction: less weight and less material
  • Building fast or yourself: no drying time, light and easy to handle
  • Also with a wet screed: the IDEAL elements can be combined with one. The pipe is recessed into the insulation, so the screed cover starts on top of the panel and you need less screed. The aluminium plates spread the heat better, and a separable layer forms between screed and elements.

Response time

Warm when you need it, off when you don’t

A wet screed is a large heat store. It is slow to get going and keeps heating when you no longer need the heat. A dry build-up has little mass above the pipe and follows demand quickly. JUPITER’s field measurements show this.

  • Better control per room. Each room heats or cools when it is needed, not hours later.
  • With a heat pump and buffer tank. The buffer tank absorbs short peaks, the floor releases the heat quickly. The heat pump runs steadily, and each room gets exactly what it asks for.
  • Ever more changeable weather. In our climate the weather changes more and more often within a day. If the sun breaks through or it cools down, the floor switches along instead of carrying on heating. The same applies to cooling.

A wet floor has a strong side too: if you want the same temperature all day, you benefit from that buffer. The difference lies in changing demand.

Heat output over a day: desired, dry build-up and wet screed The dry build-up follows the desired heat within a short time. The wet screed is slow to start and keeps heating after demand has ended.
Desired Dry (JUPITER) Wet screed
Schematic based on JUPITER field measurements, over one day. Shaded: heat the wet floor gives off when it is no longer wanted. Orange: the demand is there, but the wet floor is still lagging.

Honest advice

What to look out for

The standard build-up does not fit everywhere. In these situations you are better off choosing something else, or one of our special solutions. Talk to us first.

Dry or wet system?

Not sure which system suits your floor? This video explains the difference.

Video on YouTube. It only loads when you click play.

  • New build with enough height, where only material price counts. A wet screed with tacker panels, wire mesh or the hook-and-loop system is often cheaper per m² of material and stores more heat; we sell those systems too. If you build in timber, circular or bio-based, light, fast or yourself, dry build is a good fit. The IDEAL elements can also be combined with a wet screed.
  • A good, thick screed you do not want to raise. Milling into the existing screed adds no height, but means milling work and dust. Have the screed assessed first.
  • A walk-in shower or floor drain. NORIT is suitable up to water exposure class W1-I (bathroom floor with sealing), not W2-I and higher. For that we have special dry solutions, such as the ceramic Screed Replacement Tile (SRT) or cement-bonded boards. Ask us for advice.
  • A timber floor that flexes. Make it stiff and stable first: a dry-build floor is only as strong as the subfloor underneath. Any screed, dry or wet, will creak or crack on a floor that deflects.
  • A poorly insulated room with a thick timber floor. The floor alone may then give too little heat at a low water temperature. Calculate it first with the output calculator or let us calculate it for you. If it falls short, we add wall or ceiling heating, which can also cool.
  • Heavy loads or commercial use. The standard build-up is not designed for that. With the ceramic Screed Replacement Tile (SRT) as screed, dry build can carry extremely heavy loads, equal to or stronger than sand-cement and anhydrite screeds. Ask us for advice.

Selection guide

Which build-up suits your floor?

Choose your subfloor, the height you have and the finish that goes on top. You will see straight away which build-up fits and how high it will be.

1. Subfloor
2. Available height, excluding floor finish
35 mm
3. Floor finish

Heights are system panel plus load-spreading layer, excluding edge insulation, levelling or floor finish. The guide gives a first direction; your layout plan or our advice is decisive.

Systems

The systems side by side

All JUPITER IDEAL systems work the same way: system elements with aluminium heat-conducting plates, end elements for the bends and blank elements where no heating is needed. They differ in thickness and material.

IDEAL NEO20IDEAL EPS30IDEAL ÖKO30IDEAL STR30NORIT-TE 20 Therm GFNORIT-TE 25 Therm GF
System panel20 mm30 mm30 mm30 mm20 mm
Lowest build-up excl. floor finish³25 mm
with StrongBoard FL
35 mm
with StrongBoard FL
35 mm
with StrongBoard FL
35 mm
with StrongBoard FL
20 mm
board thickness; 3 mm levelling advised under e.g. vinyl
25 mm
board thickness; 3 mm levelling advised under e.g. vinyl
Panel materialEPS rigid foam, compressive stress 240 kPaEPS rigid foamWood fibreStrawGypsum fibre, pre-milledGypsum fibre, pre-milled
Pipe⁴ALU-PERT 16 × 2 mm · spacing 125 mm (edge zone) or 250 mm (living zone)PE-RT 12 mm · spacing 120 mmPE-RT 16 × 2 mm · laying grid 150 mm
StrengthLowest build-up with insulating panelLight and versatileImpact sound up to 28 dB better, depending on the build-upNatural, renewable materialBoard is the screed itself; fire class A1Like TE 20, with a 16 mm pipe; fire class A1
Note–––Fewer technical data publishedNo insulation in the boardNo insulation in the board; not yet in the shop
CoolingYes¹Yes¹Yes¹Yes¹Yes¹Yes¹
Price per m² of panel² € 60,26 € 57,78 € 72,60 € 76,48 € 50,07 On request
View NEO20 View EPS30 View ÖKO30 View STR30 View TE 20 Therm GF More on noritvloer.nl

¹ With a heat pump with cooling function and dew-point monitoring; see cooling. ² Edge-zone system element (RZ, spacing 125 mm, 0.5 m² each) or GF-E board (0.72 m²), excluding cutting waste, end elements, pipe and screed. Living-zone elements (AZ, spacing 250 mm) are cheaper. ³ Floating click laminate can also go directly on the IDEAL elements, on a heat foil or decoupling foil. The build-up then equals the system panel: 20 mm (NEO20) or 30 mm (EPS30, ÖKO30, STR30), plus laminate. ⁴ A PE-RT pipe without aluminium layer also fits the IDEAL elements, but we strongly advise against it. PE-RT expands much more when heated, so the pipe can tick in the aluminium plates and sit less tightly in the channels. ALU-PERT keeps its shape and is fully diffusion-tight.

From bottom to top

Example build-ups

These are a few examples, far from all the options: many more build-ups are possible in consultation with us. The orange layer is the system panel. Below it you see the total build-up up to the floor finish, and including the finish.

Renovation on a tiled floor, new tiles

Tiles + adhesive10 mm
StrongBoard FL5 mm
NEO20 system element20 mm
Existing tiled floor, flat
System panel
20 mm
Build-up
25 mm
With floor finish
≈ 35 mm

NEO20 gives the lowest build-up with an insulating panel. StrongBoard FL is suitable for tiles up to 80 × 80 cm; larger formats in consultation with us.

Timber upper floor, laminate

Laminate8 mm
StrongBoard FL5 mm
ÖKO30 system element30 mm
Timber joists with boarding, stiff
System panel
30 mm
Build-up
35 mm
With floor finish
≈ 43 mm

ÖKO30 dampens impact sound; pleasant on an upper floor. Check that the timber floor does not flex.

Concrete floor, glued vinyl

Vinyl, glued3 mm
NORIT-TE 1515 mm
EPS30 system element30 mm
Concrete, flat and dry
System panel
30 mm
Build-up
45 mm
With floor finish
≈ 48 mm

NORIT on IDEAL is a build-up agreed and approved with Lindner. For glued vinyl, follow the supplier’s requirements; levelling is sometimes needed.

Living room with parquet

Parquet 15–22 mm15–22 mm
EPS30 system element30 mm
Concrete or stiff timber floor
System panel
30 mm
Build-up
30 mm
With floor finish
45–52 mm

According to the system sheet, parquet and floorboards of 15 to 22 mm may go directly on the elements. Thicker wood heats less well.

As low as possible, tiles

Tiles + adhesive10 mm
NORIT-TE 20 Therm GF20 mm
Flat, dry subfloor
System panel
20 mm
Build-up
20 mm
With floor finish
≈ 30 mm

Here the gypsum fibre board is the screed itself, with a 12 mm pipe. It contains no insulation: only on an insulated or heated subfloor. Under smooth vinyl, for example, we advise 3 mm of levelling compound.

Thicknesses of tiles, laminate, vinyl and parquet are indicative. Edge insulation, any sound mat or levelling come on top.

Comfort

How much heat does the floor give?

The floor finish matters most. Tiles conduct well, wood and carpet insulate. The table gives the heat output at an average water temperature of 35 °C and a room at 20 °C.

Calculate it for your room

And cooling?

With a heat pump with cooling function you can also use all JUPITER IDEAL systems and NORIT Therm GF for cooling. The water must not get so cold that condensation forms on or in the floor, so you need dew-point monitoring. Floor cooling gives relief, not air-conditioning power. We calculate the cooling output per build-up for each project.

Cooling via wall or ceiling. With the same JUPITER IDEAL system on the wall or ceiling you usually cool even better than through the floor: the coolness enters the room from above or the side, and your feet stay warm. Wall and ceiling combine well with underfloor heating.

Build-up on JUPITER IDEALLiving zone
250 mm
Edge zone
125 mm
StrongBoard FL + tiles≈ 77 W/m²≈ 102 W/m²
StrongBoard FL + laminate≈ 58 W/m²≈ 73 W/m²
NORIT-TE 20 + tiles≈ 62 W/m²≈ 81 W/m²
NORIT-TE 20 + vinyl≈ 49 W/m²≈ 61 W/m²
NORIT-TE 20 + carpet≈ 41 W/m²≈ 50 W/m²
Parquet 15 mm, direct≈ 39 W/m²≈ 48 W/m²
Parquet 20 mm, direct≈ 32 W/m²≈ 39 W/m²

Values at an average water temperature of 35 °C and a room temperature of 20 °C. Applies to all IDEAL systems at the same pipe spacing. Source: JUPITER heat output tables to DIN EN 1264 (2020). Laminate and vinyl with thermal resistance 0.05 m²K/W, carpet 0.10, parquet 0.16 and 0.22. How much you need follows from the room’s heat loss.

Costs

What does dry-build underfloor heating cost?

That depends on the system, the load-spreading layer, the number of circuits and your floor finish. Below are the current shop prices, so you can do the maths yourself. The calculator works it all out and puts everything in your cart in one go.

ItemPer unitPer m²
NEO20 system element RZ (0.5 m²) € 30,13 € 60,26
EPS30 system element RZ (0.5 m²) € 28,89 € 57,78
ÖKO30 system element RZ (0.5 m²) € 36,30 € 72,60
StrongBoard FL (0.69 m²) € 20,63 € 29,90
NORIT-TE 15 dry screed board (0.72 m²) € 24,41 € 33,90
NORIT-TE 20 dry screed board (0.72 m²) € 27,02 € 37,53
NORIT-TE 20 Therm GF-E (0.72 m²) € 36,05 € 50,07
ALU-PERT system pipe 16 × 2 mm, 200 m roll € 217,32 –
Stainless steel manifold, 3 circuits € 146,28 –
Edge insulation, 50 m roll € 16,92 –
Custom layout plan€ 302,50–

Prices including VAT, as currently in the shop. Per m² = price divided by coverage, excluding cutting waste (allow about 10% extra for NORIT). End elements, pipe, manifold and edge insulation come on top; the calculator includes them.

Where does the cost advantage lie?

  • No drying time. You do not wait weeks for a wet screed before the finish can go on. That helps your planning, and sometimes saves double housing costs or rent.
  • No heating-up protocol. No days of drying out with heating before the floor is ready.
  • Install it yourself. You lay elements, pipe and screed without specialist work; preferably have an installer do the connection. That way you only pay labour for that last part.
  • Little height and weight. Often you do not need to shorten doors, adapt stairs or reinforce a timber floor because of the weight.

Compare the total costs. Looking only at material per m², a wet screed with tacker panels is often cheaper. But with dry build there is no screed pouring, no weeks of drying and no heating-up, you often do not need to adapt doors or stairs, and you can lay a lot yourself. Which is cheaper for you depends on your project: put the calculator next to a quote for a wet screed.

Layout plan

We draw up your floor: which element goes where, how the circuits run and the exact material list. Cost € 302,50. Private customers get the layout plan amount back as a discount on an order of €2,000 or more incl. VAT in IDEAL products. Business customers choose: this discount or their trade discount. Cannot be combined with other discounts. A layout plan is not a heat-loss calculation.

Order a layout plan

Delivery

Elements and boards come on a pallet, small parts as a parcel. Parcels: Netherlands €9.95, Belgium €11.95, Luxembourg €15.00, free from €350 (Benelux). Pallet delivery is outside that threshold; rates and conditions differ per country. You see the amount at checkout. Standard pallet delivery in the Benelux within 5 working days; express or a fixed date can be chosen in the cart, at a surcharge. Collection in Gouderak is also possible: €2.95, free from €350.

All delivery questions

Through your installer

Working with an installer? They can order with a business account, at trade prices excluding VAT. You can also order the materials yourself and have your installer only connect and balance the system.

Business account

Personal advice

Unsure about your floor? Call or email us

Our specialists look at your subfloor, height and floor finish with you, also if you order through an installer.

+31 (0)182 399 837info@jupiter.nl

Weekdays 08:00 – 17:00 (CET)

Frequently asked questions

Questions about dry-build underfloor heating

What is dry-build underfloor heating?

Underfloor heating without a wet screed. The pipe sits in system panels with aluminium heat-conducting plates. A dry load-spreading layer goes on top, such as StrongBoard FL or a NORIT gypsum fibre board, followed by your floor finish.

How high will my floor be?

Add up the system panel (20 or 30 mm), the load-spreading layer (5 mm StrongBoard FL or 15 to 20 mm NORIT) and your floor finish. The lowest JUPITER IDEAL build-up is 25 mm excluding floor finish: NEO20 with StrongBoard FL. If you lay floating click laminate on a heat foil or decoupling foil directly on the elements, it stays at 20 mm plus laminate. With NORIT-TE 20 Therm GF it can be from 20 mm, without insulation.

Can it go on a timber joist floor?

Yes, the build-up is light. The floor must be stiff and must not flex. In doubt about load capacity or deflection? Have a structural engineer look at it or talk to us before you order.

Is dry build also suitable for new build?

Yes, especially for timber, circular or bio-based construction and if you want to build light, fast or yourself. The floor is laid dry, separable and demountable, and can be reinstalled. Looking only at material price per m², a wet screed is often cheaper. The IDEAL elements can also be combined with a wet screed: because the pipe sits in the insulation, you need less screed and the layer stays separable.

Can I lay large tiles on it?

On StrongBoard FL up to 80 × 80 cm; larger formats in consultation with us. NORIT on IDEAL is a build-up agreed and approved with Lindner; for tiles, follow the requirements of your tile and adhesive supplier. Ask us for advice on natural stone.

Does it work with a heat pump, and can I cool with it?

Yes, dry-build underfloor heating works with low water temperatures and responds quickly. Cooling is possible with all JUPITER IDEAL systems and with NORIT Therm GF, if your heat pump can cool and there is dew-point monitoring.

How long do I wait before laying the floor finish?

There is no wet screed, so no drying time and no heating-up protocol. Lay your floor finish as soon as the screed is down and the pressure test is done. If you apply a levelling layer on NORIT Therm GF, it is ready for finishing after about 24 hours. Otherwise follow the adhesive and flooring supplier’s instructions.

Is dry build more expensive than a wet screed?

Per m² of material, usually yes. You save on drying time, heating-up, height and often labour, because you can lay a lot yourself. Whether it is cheaper overall depends on your project.

Can I install it myself?

Yes. You lay the elements, pipe and screed yourself; preferably have an installer connect it to your boiler or heat pump. Our step-by-step guide shows how.

How is it delivered?

Elements and boards by pallet, small parts as a parcel. Parcels are free from €350 in the Benelux; pallet delivery is not included, with rates and conditions per country. Standard pallet delivery in the Benelux within 5 working days.

Do I get the layout plan cost back?

As a private customer you get the layout plan amount back as a discount on an order of €2,000 or more incl. VAT in IDEAL products. Business customers choose: this discount or their trade discount. Cannot be combined with other discounts.

Ready to calculate?

Enter your rooms and see straight away what you need. In doubt? We are happy to help.